1# Plate Reader Assay Onboarding
2
3**URL:** https://cloud.ginkgo.bio/protocols/plate-reader-assay-onboarding
4**Service terms:** https://cloud.ginkgo.bio/terms/plate-reader-assay-onboarding
5**Reviewed:** 2026-09-30
6**Catalog estimate:** $399/assay; up to 4 weeks; Ginkgo Certified
7

Plate Reader Assay Onboarding

URL: https://cloud.ginkgo.bio/protocols/plate-reader-assay-onboarding Service terms: https://cloud.ginkgo.bio/terms/plate-reader-assay-onboarding Reviewed: 2026-09-30 Catalog estimate: $399/assay; up to 4 weeks; Ginkgo Certified

Raw lines 1 to 7
8## Scope
9
10Transfers an existing assay through one development iteration and one qualification
11run. The catalog mentions absorbance and luminescence, but the detailed workflow
12and terms restrict the service to a single fluorescence readout. Confirm support
13for the requested mode before ordering.
15- 96-well format; Mix -> Incubate -> Read with one incubation condition.
16- One varied factor, 2-6 levels, at least two replicates per level.
17- Endpoint or kinetics up to one hour; no true time-zero measurement or inline injection.

Scope

Transfers an existing assay through one development iteration and one qualification run. The catalog mentions absorbance and luminescence, but the detailed workflow and terms restrict the service to a single fluorescence readout. Confirm support for the requested mode before ordering.

  • 96-well format; Mix -> Incubate -> Read with one incubation condition.
  • One varied factor, 2-6 levels, at least two replicates per level.
  • Endpoint or kinetics up to one hour; no true time-zero measurement or inline injection.
Raw lines 8 to 18
19## Input and output
21Download the current intake workbook from the protocol page. Complete its
22Conditions, Reaction Components, and Varied Levels tabs with optics, gain strategy,
23volumes, buffer, incubation, reagent sources, standards, controls, and acceptance
24criteria. Confirm reader compatibility and procurement lead time.
26Ginkgo supplies raw RFU CSV data, per-level precision, control metrics, and execution
27QC. The customer determines whether the assay meets its scientific acceptance
28criteria; Ginkgo's execution QC is not a biological pass/fail certification.

Input and output

Download the current intake workbook from the protocol page. Complete its Conditions, Reaction Components, and Varied Levels tabs with optics, gain strategy, volumes, buffer, incubation, reagent sources, standards, controls, and acceptance criteria. Confirm reader compatibility and procurement lead time.

Ginkgo supplies raw RFU CSV data, per-level precision, control metrics, and execution QC. The customer determines whether the assay meets its scientific acceptance criteria; Ginkgo's execution QC is not a biological pass/fail certification.

Raw lines 19 to 28