Skill Tracer
Skills › Scientific Agent Skills › iso-standards-readiness › iso-13485.md

iso-13485.md

237 lines · skills/iso-standards-readiness/references/iso-13485.md at 5f2bc03

Open on GitHub
1# ISO 13485 Process Framework (No Standard Text)
2
3Research basis: **2026-10-01**. This reference summarizes a preparation process and
4evidence architecture. It does not reproduce ISO requirements and is not a substitute
5for the standard.
6

ISO 13485 Process Framework (No Standard Text)

Research basis: 2026-10-01. This reference summarizes a preparation process and evidence architecture. It does not reproduce ISO requirements and is not a substitute for the standard.

Raw lines 1 to 6
7## Copyright and authorized access
8
9ISO publications are copyrighted. Obtain ISO 13485 and related standards from
10[ISO](https://www.iso.org/standard/59752.html), an ISO national member, or another
11authorized source. ISO states that unauthorized copying, scanning, or distribution is
12prohibited; see [ISO copyright](https://www.iso.org/copyright.html). Do not ask an
13agent to retrieve, transcribe, summarize clause-by-clause, or store proprietary text.
15For the U.S. QMSR incorporation by reference, FDA identifies read-only access through
16the ANSI IBR portal in its
17[QMSR FAQ](https://www.fda.gov/medical-devices/quality-management-system-regulation-qmsr/quality-management-system-regulation-frequently-asked-questions).
18That access does not remove copyright or permit copying.

Copyright and authorized access

ISO publications are copyrighted. Obtain ISO 13485 and related standards from ISO, an ISO national member, or another authorized source. ISO states that unauthorized copying, scanning, or distribution is prohibited; see ISO copyright. Do not ask an agent to retrieve, transcribe, summarize clause-by-clause, or store proprietary text.

For the U.S. QMSR incorporation by reference, FDA identifies read-only access through the ANSI IBR portal in its QMSR FAQ. That access does not remove copyright or permit copying.

Raw lines 7 to 19
20## Current edition and the 2021 European amendment
22- [ISO 13485:2016](https://www.iso.org/standard/59752.html) is Edition 3,
23 published March 2016. ISO completed its 2025 systematic review and confirmed the
24 edition on 2025-10-31; it remains current as of this research date.
25- Do not call **EN ISO 13485:2016/A11:2021** an ISO international Amendment 1.
26 It is a European amendment to the EN adoption. The current EU harmonised-standards
27 lists include EN ISO 13485:2016, AC:2018, and A11:2021. Verify the current OJEU
28 citation on the Commission's
29 [harmonised standards page](https://health.ec.europa.eu/medical-devices-topics-interest/harmonised-standards_en).
30- FDA incorporated ISO 13485:2016(E), Third edition, March 1, 2016. A later ISO or
31 EN publication does not silently change the edition incorporated in Part 820.
33Record exact publisher, title, edition, amendment/corrigendum, authorized location,
34access date, source owner, currency-review date, impact decision, and approval.

Current edition and the 2021 European amendment

  • ISO 13485:2016 is Edition 3, published March 2016. ISO completed its 2025 systematic review and confirmed the edition on 2025-10-31; it remains current as of this research date.
  • Do not call EN ISO 13485:2016/A11:2021 an ISO international Amendment 1. It is a European amendment to the EN adoption. The current EU harmonised-standards lists include EN ISO 13485:2016, AC:2018, and A11:2021. Verify the current OJEU citation on the Commission's harmonised standards page.
  • FDA incorporated ISO 13485:2016(E), Third edition, March 1, 2016. A later ISO or EN publication does not silently change the edition incorporated in Part 820.

Record exact publisher, title, edition, amendment/corrigendum, authorized location, access date, source owner, currency-review date, impact decision, and approval.

Raw lines 20 to 35
36## Hard boundary
38This skill and its files cannot:
40- certify a QMS or issue/validate a certificate;
41- determine legal or regulatory applicability, device classification, reportability,
42 conformity route, market access, or product authorization;
43- replace the authorized management representative, top management, RA/QA, legal
44 counsel, competent/regulatory authority, notified body, MDSAP Auditing
45 Organization, accreditation body, or certification body;
46- infer effective implementation from a document title, keyword, template, checklist,
47 or script result; or
48- claim compliance, conformity, certification, or inspection readiness.
50Use outputs as a list of evidence questions for accountable human review.

Hard boundary

This skill and its files cannot:

  • certify a QMS or issue/validate a certificate;
  • determine legal or regulatory applicability, device classification, reportability, conformity route, market access, or product authorization;
  • replace the authorized management representative, top management, RA/QA, legal counsel, competent/regulatory authority, notified body, MDSAP Auditing Organization, accreditation body, or certification body;
  • infer effective implementation from a document title, keyword, template, checklist, or script result; or
  • claim compliance, conformity, certification, or inspection readiness.

Use outputs as a list of evidence questions for accountable human review.

Raw lines 36 to 51
52## Keep the assurance regimes separate
54`references/assurance-lanes.md` holds the full lane table across every standard in this
55skill, including how certification differs from laboratory accreditation. The
56device-specific detail follows here.

Keep the assurance regimes separate

references/assurance-lanes.md holds the full lane table across every standard in this skill, including how certification differs from laboratory accreditation. The device-specific detail follows here.

Raw lines 52 to 57
58### ISO 13485 management-system certification
60A certification body audits the defined QMS scope against the authorized standard and
61its certification scheme. The certificate is limited to its stated organization, sites,
62activities, products/technical areas, standard edition, and validity. Certification is
63not FDA approval, an FDA inspection exemption, an MDSAP audit, an EU device
64certificate, or a legal-applicability decision.
66For accredited ISO 13485 certification, verify the certification body's accreditation
67scope. As of 2026, Global Accreditation Cooperation Incorporated has replaced IAF
68and ILAC operationally. Its document library now lists Global ACI-TECH-3-006 (M) and
69Global ACI-TECH-3-007 (M), successors to IAF MD 8:2023 and MD 9:2023, both
70implemented 2026-08-28. These documents concern
71accreditation and certification-body practice, not product authorization.

ISO 13485 management-system certification

A certification body audits the defined QMS scope against the authorized standard and its certification scheme. The certificate is limited to its stated organization, sites, activities, products/technical areas, standard edition, and validity. Certification is not FDA approval, an FDA inspection exemption, an MDSAP audit, an EU device certificate, or a legal-applicability decision.

For accredited ISO 13485 certification, verify the certification body's accreditation scope. As of 2026, Global Accreditation Cooperation Incorporated has replaced IAF and ILAC operationally. Its document library now lists Global ACI-TECH-3-006 (M) and Global ACI-TECH-3-007 (M), successors to IAF MD 8:2023 and MD 9:2023, both implemented 2026-08-28. These documents concern accreditation and certification-body practice, not product authorization.

Raw lines 58 to 72
73### FDA QMSR inspection and compliance
75The [QMSR](https://www.fda.gov/medical-devices/postmarket-requirements-devices/quality-management-system-regulation-qmsr)
76became effective **2026-02-02** and FDA began enforcement on that date. The current
77[21 CFR Part 820](https://www.ecfr.gov/current/title-21/chapter-I/subchapter-H/part-820)
78is titled *Quality Management System Regulation*. It incorporates ISO 13485:2016
79and contains FDA scope, definitions, incorporation, QMS, record, and
80labeling/packaging provisions. Other applicable FDA requirements still matter.
82On 2026-02-02 FDA stopped using QSIT and began the inspection process in
83[Compliance Program 7382.850](https://www.fda.gov/media/80195/download?attachment).
84This is now a post-effective-date implementation state, not a future transition.
85FDA may inspect QMS records created before the effective date and records that had
86previously been exempt from routine review under the old regulation, as explained in
87the QMSR FAQ.
89Do not use the former 21 CFR 820 section structure as a current requirements map.
90Inventory legacy QSR/QSIT references, disposition them under change control, and use
91the current eCFR, incorporated edition, and linked current FDA regulations.

FDA QMSR inspection and compliance

The QMSR became effective 2026-02-02 and FDA began enforcement on that date. The current 21 CFR Part 820 is titled Quality Management System Regulation. It incorporates ISO 13485:2016 and contains FDA scope, definitions, incorporation, QMS, record, and labeling/packaging provisions. Other applicable FDA requirements still matter.

On 2026-02-02 FDA stopped using QSIT and began the inspection process in Compliance Program 7382.850. This is now a post-effective-date implementation state, not a future transition. FDA may inspect QMS records created before the effective date and records that had previously been exempt from routine review under the old regulation, as explained in the QMSR FAQ.

Do not use the former 21 CFR 820 section structure as a current requirements map. Inventory legacy QSR/QSIT references, disposition them under change control, and use the current eCFR, incorporated edition, and linked current FDA regulations.

Raw lines 73 to 92
93### MDSAP regulatory audit
95MDSAP is a regulatory audit conducted by an MDSAP-recognized Auditing
96Organization for participating jurisdictions. The current official
97[MDSAP Audit Approach](https://www.mdsap.global/documents/library/audit-approach)
98is **MDSAP AU P0002.011**, version date **2026-08-03**. It uses a process-based
99approach and includes jurisdiction-specific requirements.
101An ISO certificate alone is not an MDSAP audit. FDA inspections under QMSR do not
102follow the MDSAP audit plan, and FDA does not issue ISO 13485 certificates. MDSAP
103participation does not eliminate every possible regulatory inspection or
104product-specific obligation.

MDSAP regulatory audit

MDSAP is a regulatory audit conducted by an MDSAP-recognized Auditing Organization for participating jurisdictions. The current official MDSAP Audit Approach is MDSAP AU P0002.011, version date 2026-08-03. It uses a process-based approach and includes jurisdiction-specific requirements.

An ISO certificate alone is not an MDSAP audit. FDA inspections under QMSR do not follow the MDSAP audit plan, and FDA does not issue ISO 13485 certificates. MDSAP participation does not eliminate every possible regulatory inspection or product-specific obligation.

Raw lines 93 to 105
106### EU MDR/IVDR conformity assessment
108The MDR and IVDR impose legal obligations beyond a generic QMS. Use the current
109consolidated regulation and current, product-specific conformity route:
111- [Regulation (EU) 2017/745 (MDR)](https://eur-lex.europa.eu/eli/reg/2017/745/2026-07-19/eng)
112 — indexed consolidation dated 2026-07-19; retrieve the controlled text before use.
113- [Regulation (EU) 2017/746 (IVDR)](https://eur-lex.europa.eu/eli/reg/2017/746/2025-01-10/eng)
114 — indexed consolidation dated 2025-01-10; see the ledger's retrieval limitation.
115- [MDCG guidance index](https://health.ec.europa.eu/medical-devices-sector/new-regulations/guidance-mdcg-endorsed-documents-and-other-guidance_en)
116 — guidance is not legally binding and is versioned/revised.
118Notified bodies are designated by Member States for specified legislation,
119conformity-assessment tasks, and designation codes. Verify current scope in
120[NANDO](https://webgate.ec.europa.eu/single-market-compliance-space/notified-bodies).
121Accreditation or ISO certification does not by itself confer notified-body designation
122or establish EU product conformity.

EU MDR/IVDR conformity assessment

The MDR and IVDR impose legal obligations beyond a generic QMS. Use the current consolidated regulation and current, product-specific conformity route:

Notified bodies are designated by Member States for specified legislation, conformity-assessment tasks, and designation codes. Verify current scope in NANDO. Accreditation or ISO certification does not by itself confer notified-body designation or establish EU product conformity.

Raw lines 106 to 123
124### Product- and market-specific requirements
126Product classification, intended purpose, claims, software, cybersecurity, clinical or
127performance evidence, biocompatibility, electrical safety, sterilization, UDI,
128registration, reporting, and other controls depend on the device and jurisdiction.
129Manage these in a separately approved applicability matrix. Never assume this
130framework is complete for a product.

Product- and market-specific requirements

Product classification, intended purpose, claims, software, cybersecurity, clinical or performance evidence, biocompatibility, electrical safety, sterilization, UDI, registration, reporting, and other controls depend on the device and jurisdiction. Manage these in a separately approved applicability matrix. Never assume this framework is complete for a product.

Raw lines 124 to 131
132## QMS evidence domains
134The domains below are workflow topics, not clause text. An authorized standard copy
135and jurisdiction-specific sources remain the audit criteria.

QMS evidence domains

The domains below are workflow topics, not clause text. An authorized standard copy and jurisdiction-specific sources remain the audit criteria.

Raw lines 132 to 136
137### Scope, governance, and roles
139Evidence should identify legal entities, sites, products/families, lifecycle activities,
140outsourced processes, markets considered, interfaces, top-management authority,
141management representative, RA/QA ownership, delegates, independence, and
142escalation. Every applicability or not-applicable decision needs a named owner,
143rationale, source/version, evidence, date, and approval.

Scope, governance, and roles

Evidence should identify legal entities, sites, products/families, lifecycle activities, outsourced processes, markets considered, interfaces, top-management authority, management representative, RA/QA ownership, delegates, independence, and escalation. Every applicability or not-applicable decision needs a named owner, rationale, source/version, evidence, date, and approval.

Raw lines 137 to 144
145### Document and record control
147Control authoring, review, approval, effective use, distribution, revision,
148obsolescence, external sources, retention, integrity, security, retrieval, correction,
149audit trails, backup/recovery, and disposition. Preserve source/version evidence and
150license restrictions. Link changes to training and validation before effective use.

Document and record control

Control authoring, review, approval, effective use, distribution, revision, obsolescence, external sources, retention, integrity, security, retrieval, correction, audit trails, backup/recovery, and disposition. Preserve source/version evidence and license restrictions. Link changes to training and validation before effective use.

Raw lines 145 to 151
152### Risk management
154Integrate product and process risk with intended use, design, suppliers, production,
155software, validation, complaints, postmarket data, CAPA, and change control.
156[ISO 14971:2019](https://www.iso.org/standard/72704.html), Edition 3, was confirmed
157in 2025. For EU work, distinguish EN ISO 14971:2019/A11:2021; the A11 amendment is
158European and does not replace a product-specific legal analysis.

Risk management

Integrate product and process risk with intended use, design, suppliers, production, software, validation, complaints, postmarket data, CAPA, and change control. ISO 14971:2019, Edition 3, was confirmed in 2025. For EU work, distinguish EN ISO 14971:2019/A11:2021; the A11 amendment is European and does not replace a product-specific legal analysis.

Raw lines 152 to 159
160### Design and development
162Maintain approved planning, responsibilities, inputs, outputs, review, verification,
163validation, transfer, changes, and traceability. Evidence should show that risk
164controls and postmarket learning feed the design/change system. A claimed
165not-applicable design process requires authorized scope and regulatory review.

Design and development

Maintain approved planning, responsibilities, inputs, outputs, review, verification, validation, transfer, changes, and traceability. Evidence should show that risk controls and postmarket learning feed the design/change system. A claimed not-applicable design process requires authorized scope and regulatory review.

Raw lines 160 to 166
167### Suppliers and outsourced processes
169Use risk-based selection, evaluation, controls, purchasing information, acceptance,
170change notification, sub-tier flow-down, monitoring, re-evaluation,
171nonconformity/CAPA, and business-continuity evidence. Outsourcing does not transfer
172the organization's accountability for its controlled process.

Suppliers and outsourced processes

Use risk-based selection, evaluation, controls, purchasing information, acceptance, change notification, sub-tier flow-down, monitoring, re-evaluation, nonconformity/CAPA, and business-continuity evidence. Outsourcing does not transfer the organization's accountability for its controlled process.

Raw lines 167 to 173
174### Production, service, and validation
176Define infrastructure, work environment, contamination/cleanliness where relevant,
177controlled instructions, acceptance/release, labeling/packaging, preservation,
178installation, servicing, process validation, monitoring/measurement equipment, and
179change/revalidation triggers. Evidence must be product/process-specific.

Production, service, and validation

Define infrastructure, work environment, contamination/cleanliness where relevant, controlled instructions, acceptance/release, labeling/packaging, preservation, installation, servicing, process validation, monitoring/measurement equipment, and change/revalidation triggers. Evidence must be product/process-specific.

Raw lines 174 to 180
181### Software used in the QMS or production
183Record intended use, risk, requirements, configuration, access, data integrity,
184verification/validation, acceptance, release, incident handling, backup/recovery,
185supplier controls, and change/revalidation. A software inventory or vendor
186certificate alone is not validation.

Software used in the QMS or production

Record intended use, risk, requirements, configuration, access, data integrity, verification/validation, acceptance, release, incident handling, backup/recovery, supplier controls, and change/revalidation. A software inventory or vendor certificate alone is not validation.

Raw lines 181 to 187
188### Identification and traceability
190Define the required extent using approved product and jurisdictional decisions. Link
191materials/components, process records, acceptance/release, distribution, servicing,
192complaints, corrections/removals, and postmarket records as applicable.

Identification and traceability

Define the required extent using approved product and jurisdictional decisions. Link materials/components, process records, acceptance/release, distribution, servicing, complaints, corrections/removals, and postmarket records as applicable.

Raw lines 188 to 193
194### Complaints, vigilance, and postmarket
196Control intake, evaluation, investigation, product/risk impact, trend analysis,
197reportability decisions, communications, advisory/field actions, and feedback to
198risk, design, production, suppliers, CAPA, and management review. Authorized roles
199must make jurisdiction-specific reporting decisions.

Complaints, vigilance, and postmarket

Control intake, evaluation, investigation, product/risk impact, trend analysis, reportability decisions, communications, advisory/field actions, and feedback to risk, design, production, suppliers, CAPA, and management review. Authorized roles must make jurisdiction-specific reporting decisions.

Raw lines 194 to 200
201### Nonconformity and CAPA
203Separate correction/containment from cause-directed action. Preserve scope, risk and
204reportability review, investigation, supported cause or conclusion, action ownership,
205change links, implementation evidence, pre-defined effectiveness criteria,
206independent review, and closure approval. Pending or ineffective checks cannot
207support closure.

Nonconformity and CAPA

Separate correction/containment from cause-directed action. Preserve scope, risk and reportability review, investigation, supported cause or conclusion, action ownership, change links, implementation evidence, pre-defined effectiveness criteria, independent review, and closure approval. Pending or ineffective checks cannot support closure.

Raw lines 201 to 208
209### Internal audit and management review
211Use a risk-based audit program, objective criteria/scope/sampling, competent and
212independent auditors, findings, corrections/CAPA, and effectiveness follow-up.
213Management review should use controlled inputs and record decisions, resources,
214actions, owners, dates, and follow-up. Neither activity can be replaced by a
215checklist-generated score.

Internal audit and management review

Use a risk-based audit program, objective criteria/scope/sampling, competent and independent auditors, findings, corrections/CAPA, and effectiveness follow-up. Management review should use controlled inputs and record decisions, resources, actions, owners, dates, and follow-up. Neither activity can be replaced by a checklist-generated score.

Raw lines 209 to 216
217### Training, competence, and change control
219Define role competence, training need, completion, effectiveness, authorization, and
220records. Changes should assess source/version, product/risk, validation, software,
221supplier, document, record, training, postmarket, regulatory, and certification/audit
222impacts before implementation.

Training, competence, and change control

Define role competence, training need, completion, effectiveness, authorization, and records. Changes should assess source/version, product/risk, validation, software, supplier, document, record, training, postmarket, regulatory, and certification/audit impacts before implementation.

Raw lines 217 to 223
224## Evidence quality rule
226For each domain, require:
2281. defined scope and accountable owner;
2292. approved process/document status;
2303. actual implementation records, not only a procedure;
2314. traceable evidence IDs and controlled locations;
2325. source/edition/version and currency-review evidence;
2336. approval and effective dates;
2347. open gaps, decisions, and change/CAPA links; and
2358. sampling across products, sites, time periods, and risk where justified.
237Use `references/source-ledger.md` for the dated official-source baseline.

Evidence quality rule

For each domain, require:

  1. defined scope and accountable owner;
  2. approved process/document status;
  3. actual implementation records, not only a procedure;
  4. traceable evidence IDs and controlled locations;
  5. source/edition/version and currency-review evidence;
  6. approval and effective dates;
  7. open gaps, decisions, and change/CAPA links; and
  8. sampling across products, sites, time periods, and risk where justified.

Use references/source-ledger.md for the dated official-source baseline.

Raw lines 224 to 237