simulation_workflow.md
357 lines · skills/fluidsim/references/simulation_workflow.md at 5f2bc03
Most marks come from matching words in the file, so treat them as pointers.
Bounded simulation, pilot, and restart workflow
Raw lines 1 to 21. Define the scientific contract
Before code, record:
- Equations, dependent variables, approximations, and solver key.
- Units for every dimensional quantity, or reference scales and a complete nondimensionalization map.
- Domain lengths, geometry, periodic boundary conditions, and symmetries.
- Initial-condition construction, constraints, amplitude/spectrum, and seed.
- Forcing field, band, normalization, correlation, and expected/measured input.
- Dissipation and any hypo-/hyper-viscosity.
- Observables and acceptance thresholds.
- Conservation/budget identities and expected numerical residual behavior.
- Grid, dealiasing, timestep/CFL, and refinement plan.
- Independent benchmark or verification target.
Do not proceed from a prompt that only says “simulate turbulence” or supplies a Reynolds number without its definition and scaling.
Raw lines 3 to 212. Declare operational bounds
Every plan must explicitly bound:
- CPU cores.
- MPI ranks and threads/rank.
- Total and per-rank RAM envelope.
- Disk bytes and file/inode count.
- Wall time and FluidSim
max_elapsed. - Grid dimensions and total points.
- State snapshot and diagnostic save periods.
- Safe output root and subdirectory.
The bundled JSON schema requires these fields. Start from:
python3 scripts/solver_config_validator.py --exampleSave the reviewed JSON locally, then:
python3 scripts/solver_config_validator.py --config config.json
python3 scripts/grid_resource_estimator.py --config config.json
python3 scripts/simulation_dry_run.py --config config.json --output run.pyThe resource estimator reports an approximate allocation/storage model, not measured peaks or enforced quotas. Save records are counted independently of the declared file limit; exceeding a limit is a failure, never a truncated estimate. Enabled diagnostics outside physical fields, spectra, spectral budget, and spatial means require a separate estimate. Iteration-only termination does not provide the time horizon this storage model needs.
The generator does not import FluidSim or run anything. The generated script prints a JSON dry run by default. Execution requires both --execute and the exact reviewed config ID. An MPI plan is only a command preview; the tool never invokes a launcher or scheduler.
3. Verify the locked environment
In an isolated exact environment:
from importlib.metadata import version
from fluidfft import get_methods
assert version("fluidsim") == "0.9.0"
assert version("fluidfft") == "0.4.5"
print(sorted(get_methods()))Record registered FFT methods, then load and exercise the chosen method. get_methods() lists entry points even when an optional dependency is absent (for example Dask). Importing a package is not enough: construct the selected solver's defaults and run its tiny transform/solver smoke.
4. Tiny no-output serial smoke
After approval, use a trivial, bounded state:
from fluidsim.solvers.ns2d.solver import Simul
params = Simul.create_default_params()
params.oper.nx = params.oper.ny = 8
params.oper.Lx = params.oper.Ly = 2.0
params.oper.coef_dealiasing = 2 / 3
params.time_stepping.USE_CFL = False
params.time_stepping.deltat0 = 0.001
params.time_stepping.deltat_max = 0.001
params.time_stepping.t_end = 0.001
params.time_stepping.max_elapsed = "00:01:00"
params.init_fields.type = "constant"
params.init_fields.constant.value = 0.0
params.output.HAS_TO_SAVE = False
params.output.ONLINE_PLOT_OK = False
sim = Simul(params)
sim.time_stepping.start()This checks import, FFT construction, initialization, and one bounded step. It does not test the intended physics, forcing, conservation, convergence, performance, output, or restart.
Raw lines 79 to 1075. Tiny output/restart smoke
Use a dedicated empty output root under a quota. Keep:
params.output.sub_directorya safe one-component study identifier.ONLINE_PLOT_OK = Falsefor unattended runs.- Short
t_end, shortmax_elapsed, and low resolution. - One or two physical-state saves and a bounded scalar diagnostic.
- Spectra/budget outputs disabled unless they are the feature being tested.
Inspect before analysis:
python3 scripts/output_inventory.py --path fluidsim-runs
python3 scripts/budget_summary.py --path fluidsim-runsConfirm exact filenames and growth. FluidSim 0.9 defaults to state_phys_t*.nc for physical states; spectra remain HDF5.
6. Representative scientific pilot
Increase only enough to exercise the intended:
- Initial-condition path.
- Forcing type and injection normalization.
- Solver-specific state and outputs.
- FFT backend.
- Checkpoint and restart.
- Analysis code.
During and after the pilot, check:
- CFL and
deltathistory against all relevant wave/advection/diffusion limits. - Divergence or other constraints.
- Energy/enstrophy/scalar/potential-energy budgets as appropriate.
- Measured forcing input and dissipation.
- Spectral tails and dealiasing contamination.
- Runtime, peak RSS, per-rank imbalance, file count, and disk growth.
- NaN/Inf, stalled advancement, unexpected truncation, and incomplete files.
A passing pilot permits planning a refinement study; it does not validate a production run.
Raw lines 128 to 1517. Running a reviewed serial plan
The generated script is deliberately gated:
python3 run.py
python3 run.py --execute --acknowledge-config-id REVIEWED_CONFIG_IDAt execution, it verifies the installed FluidSim/FluidFFT versions, assigns reviewed thread limits before NumPy import, and checks the actual MPI size. Restart paths are anchored to the script directory and rehashed before loading; use a matching provenance.restart.path and init_fields.from_file.path. These are preflight checks, not RAM/disk/CPU quota enforcement.
The first command is dry-run only. The second is a real simulation and must be issued by the user or approved operator after reviewing limits and output destination.
Never silently increase resolution, duration, save frequency, rank count, or wall time after approval.
Raw lines 152 to 1738. Read-only loading
Use the lightweight loader:
from fluidsim import load_sim_for_plot
sim = load_sim_for_plot(
"run-directory",
merge_missing_params=False,
hide_stdout=True,
)Use native loaders only on trusted run metadata: they import the recorded solver/extension modules. For untrusted files, start with the bounded metadata helpers instead.
Official 0.9 source shows that it:
- Loads solver and parameters from the result directory.
- Sets a constant initialization and coarse operator.
- Sets
NEW_DIR_RESULTS = False. - Sets
output.HAS_TO_SAVE = FalseandONLINE_PLOT_OK = False. - Selects default/sequential FFT for plotting.
- Can merge missing defaults for older runs when explicitly requested.
merge_missing_params=True helps load old metadata but does not prove that an old result is scientifically or numerically equivalent under the new version.
9. State-bearing loading
from fluidsim import load_state_phys_file
sim = load_state_phys_file(
"run-directory",
t_approx="last",
modif_save_params=True,
merge_missing_params=False,
init_with_initialized_state=True,
hide_stdout=True,
)This constructs a full-resolution operator and loads state; it can be expensive. With the default modif_save_params=True, saving and online plotting are disabled. Loading a state object is not the same as approving a restart.
10. Reviewed Python restart
First compare metadata:
python3 scripts/restart_compatibility.py \
--source state_phys_t001.000.nc \
--target-config restart-config.jsonThe checker uses required state keys and dataset shapes/dtypes, not just a nonempty /state_phys group. It requires grid/domain metadata and finite state time. For a directory it examines at most 256 entries in that run, selecting by stored time/iteration rather than filename ordering; ambiguous latest states require an explicit file. Soft/external links are rejected. For time-correlated forcing, /state_params/forcing must contain seed0, seed1, and t_last_change. A JSON manifest must provide state.dataset_metadata entries with shape and numeric: true for each required field; its digest is a declaration, unlike a digest computed from the checkpoint.
Then, after approval:
from fluidsim import load_for_restart
params, Simul = load_for_restart(
"run-directory",
t_approx="last",
merge_missing_params=False,
)
params.time_stepping.t_end = 2.0
params.time_stepping.max_elapsed = "00:10:00"
params.NEW_DIR_RESULTS = True
sim = Simul(params)
sim.time_stepping.start()load_for_restart reads parameters from /info_simul/params, sets init_fields.type = "from_file", points it to the selected state file, and by default sets NEW_DIR_RESULTS = False. Explicitly choose append versus new directory. Never append to an irreplaceable run without a backup and checksum.
Record:
- Parent run ID/path and state SHA-256.
- Selected state time/iteration.
- Parent and child package/backend/platform versions.
- Every changed parameter and justification.
- Append/new-directory decision.
- Forcing state continuity.
- Child output inventory and lock/script/config hashes.
FluidSim 0.9.0 stores “state parameters” in restarting files. FluidSim 0.8.6 fixed incorrect restart of time-correlated forcing; old checkpoints need extra review.
Raw lines 223 to 27911. Upstream restart CLI
Safe first action:
fluidsim-restart --only-check run-directory --t_end 2.0Current options include --only-check, --only-init, --new-dir-results, --t_approx, target/additive time or iteration bounds, --merge-missing-params, and --max-elapsed.
Avoid --modify-params with any untrusted or generated text. Official source passes that string to Python code execution. The bundled generator never emits this option.
The CLI does not supply scheduler resource limits. Running it under MPI or a scheduler remains a separate, explicit operational action.
Raw lines 280 to 29812. Resolution changes
Do not change oper.nx/ny/nz and treat an old state file as directly compatible. FluidSim provides:
fluidsim-modif-resolution run-directory 5/4This creates a new state at modified resolution. Before use:
- Inventory free memory and disk; interpolation/FFT can be expensive.
- Preserve the original state.
- Record coefficient, source/output hashes, and implementation version.
- Check domain, state keys, normalization, and constraints.
- Treat the child as a new numerical experiment.
- Re-run transient, budget, spectral, and refinement checks.
Do not run this automatically or on a large state by default.
Raw lines 299 to 31813. MPI/HPC handoff
After a serial pilot:
- Ask the site scheduler for the intended allocation; never submit from this skill.
- Verify the pinned MPI/FluidFFT environment inside that allocation.
- Run a manually launched tiny two-rank smoke.
- Benchmark candidate FFT methods on representative small shapes.
- Confirm decomposition compatibility and local array sizes.
- Set explicit process/thread affinity.
- Set memory/rank, wall time, scratch, output quota, and signal/checkpoint behavior.
- Use a short restartable pilot before scale-up.
The 2019 FluidSim/FluidFFT performance results are hardware- and shape-specific. Do not extrapolate their wall times or fastest backend to another cluster.
Raw lines 319 to 336Failure and interruption handling
- Preserve logs and last complete checkpoint.
- Treat a signal-terminated or wall-time-limited run as incomplete until the checkpoint is inventoried and validated.
- Do not pick the lexically latest file without checking its time, iteration, HDF5 readability, and checksum.
- Never overwrite the parent state during recovery.
- Re-run the compatibility checker before every continuation.
- Explain any budget discontinuity at the restart boundary.
Sources (verified 2026-10-01)
- FluidSim user tutorial.
- Restart and resolution change.
- FluidSim load/restart source.
- Restart CLI source.
- FluidSim 0.9 release notes.
- Mohanan et al., FluidSim primary paper, published 2019-04-26; performance claims are limited to its documented benchmark setup.