Raw lines 1 to 5Measurement contract
Record:
- conductance versus resistance, physical unit, range, and calibration;
- constant-voltage/current system and electrode material/area;
- palmar/plantar or other site, laterality, placement, and skin preparation;
- sampling rate, hardware filters, temperature, humidity, acclimation, and movement;
- missing/detached/saturated intervals; and
- participant/task factors and response definition.
Do not infer microsiemens from EDA or compare arbitrary sensor units with published µS thresholds. Sensor site, hardware, environment, and population require validation.
Default stable pipeline
signals, info = nk.eda_process(
eda,
sampling_rate=100,
method="neurokit",
)In stable 0.2.13 the NeuroKit pipeline performs cleaning, high-pass tonic/phasic decomposition, and NeuroKit SCR detection. It does not use cvxEDA by default.
The pinned default schema observed:
EDA_Raw, EDA_Clean, EDA_Tonic, EDA_Phasic,
SCR_Onsets, SCR_Peaks, SCR_Height, SCR_Amplitude,
SCR_RiseTime, SCR_Recovery, SCR_RecoveryTimeinfo was a flat dict containing SCR arrays plus sampling_rate. Treat this as a default 0.2.13 observation, not a universal schema.
There is no public eda_quality() in stable 0.2.13. Quality must combine acquisition metadata, missing/flat/clipped/motion checks, raw/clean overlays, decomposition plausibility, and response review.
Make decomposition explicit
clean = nk.eda_clean(eda, sampling_rate=100, method="neurokit")
components = nk.eda_phasic(
clean,
sampling_rate=100,
method="highpass",
)eda_clean() options include neurokit, biosppy, and none. The NeuroKit path uses a 3 Hz low-pass, and skips it below 7 Hz.
eda_phasic() returns a DataFrame with EDA_Tonic and EDA_Phasic. Methods include:
highpass: default stable method; phasic high-pass separation;smoothmedian: median-smoothed tonic estimate;cvxeda: convex optimization; needs optionalcvxopt;sparseda: sparse decomposition.
These methods estimate different latent components and are not interchangeable. Report method, all kwargs, optional dependency versions, convergence/failure behavior, and sensitivity. Do not call one decomposition “physiologically true” without appropriate validation.
Raw lines 49 to 74SCR detection
markers, peak_info = nk.eda_peaks(
components["EDA_Phasic"],
sampling_rate=100,
method="neurokit",
amplitude_min=0.1,
)Stable methods include neurokit, gamboa2008, kim2004, vanhalem2020, and nabian2018. For neurokit and kim2004, amplitude_min is a fraction relative to the largest detector-specific candidate in the analyzed signal—not an absolute µS threshold. In stable source, neurokit thresholds peak prominence, whereas kim2004 thresholds phasic peak height. Neither is a common absolute onset-to-peak amplitude cutoff. Other supported methods ignore amplitude_min.
eda_peaks() returns (signals, info):
- marker/feature DataFrame:
SCR_Onsets,SCR_Peaks,SCR_Height,SCR_Amplitude,SCR_RiseTime,SCR_Recovery,SCR_RecoveryTime; - info dict: event-indexed arrays and sampling rate.
Marker columns are same-length arrays; feature values are placed at relevant marker locations and are otherwise zero, not missing, in stable 0.2.13. Invalid feature values at a detected response can still be NaN. Use info for event-level arrays. Do not average same-length feature columns as if every sample were an independent response.
eda_fixpeaks() is documented as a placeholder that does not currently correct EDA peaks.
Missingness and artifacts
EDA motion/electrode artifacts can resemble fast responses, while detachment can look flat. Before decomposition:
- inspect raw units, range, clipping, steps, flatlines, and missing runs;
- segment long discontinuities;
- annotate motion, temperature changes, and contact problems;
- avoid broad interpolation across SCR morphology; and
- keep an artifact/validity mask through epoching.
Filtering cannot restore a detached or saturated channel. A low response count can be physiological, methodological, or a sensor failure; it is not automatically a “non-responder.”
Raw lines 107 to 121Event-related EDA
Create epochs only after event and signal clocks are aligned:
epochs = nk.epochs_create(
signals,
events,
sampling_rate=100,
epochs_start=-1,
epochs_end=10,
baseline_correction=False,
)
features = nk.eda_eventrelated(epochs)Stable event-related output is conditional on available columns. Documented features include EDA_SCR, first-response amplitude/time/rise/recovery fields, tonic/phasic summaries, labels, conditions, and event onset. Inspect features.columns.
Prespecify response latency/window, overlap handling, baseline approach, minimum amplitude definition, non-response coding, and trial artifact rules. Slow responses can overlap adjacent events; a peak in a window is not automatically elicited by that event.
Raw lines 122 to 145Interval analysis and sympathetic index
features = nk.eda_intervalrelated(signals, sampling_rate=100)The pinned official example showed six columns, including SCR count/amplitude, EDA_Tonic_SD, EDA_Sympathetic, EDA_SympatheticN, and EDA_Autocorrelation; output depends on duration and available columns.
eda_sympathetic() supports posada and ghiasi, with a default 0.045–0.25 Hz band. Stable posada returns NaN when duration is 64 seconds or less, despite a warning referring to 60 seconds. ghiasi uses 60-second STFT windows with 59-second overlap. The helper conservatively requires more than 64 seconds for either method; this is a software guard, not a universal validity threshold. Report exact usable duration, frequency band, estimator, normalization, and units. Do not turn this index into a direct clinical sympathetic-state measure.
Bounded pipeline
python skills/neurokit2/scripts/eda_pipeline.py \
--input deidentified.csv --column EDA --root . --deidentified \
--sampling-rate 100 --unit uS \
--clean-method neurokit --phasic-method highpass \
--peak-method neurokit --amplitude-min 0.1The helper rejects missing/non-finite samples, records the observed schema, and makes decomposition/threshold semantics explicit.
Only neurokit and kim2004 apply --amplitude-min; the report marks it inactive for other detectors. Synthetic generation passes both duration and integer sample count: supplying length alone does not update NeuroKit2's default 10-second time axis, drift, or SCR placement. Flat/no-response inputs can raise a detector error; do not reinterpret that failure as a validated physiological zero-response count.
Interpretation boundary
EDA indexes eccrine sweat-gland activity under the recording conditions. It does not uniquely identify stress, emotion, deception, pain, diagnosis, or intent. Compare within a theory-driven design with contextual measures and validated preprocessing. Do not use this workflow for clinical/driver/workplace monitoring or medical-device validation.
Raw lines 183 to 190Sources checked 2026-10-01
- Official EDA API
- Official SCR example
- Stable v0.2.13 EDA source
- SPR Ad Hoc Committee (2012), publication recommendations
- Greco et al. (2016), cvxEDA
- NeuroKit2 main paper
- [Stable
eda_simulate.pyimplementation](https://github.com/neuropsychology/NeuroKit/blob/v0.2.13/neurokit2/eda/eda_simulate.py)